產(chǎn)品名稱(chēng) : FSD-2312
類(lèi)型 : 壓電蜂鳴器
驅(qū)動(dòng)方式 : 有源蜂鳴器
工藝 : 引線(xiàn)蜂鳴器
尺寸范圍 : 20-30mm
A. SCOPE 
This specification applies piezo buzzer, FSD-2312
 
B. SPECIFICATION
| No. | Item  | Unit  | Specification  | Condition  | 
1  | Oscillation Frequency  | KHz  | 3.0±0.5  | |
2  | Operating Voltage  | VDC  | 3 ~ 20  | |
3  | Rated Voltage | VDC  | 12  | |
4  | Current Consumption  | mA  | MAX. 10  | at Rated Voltage  | 
5  | Sound Pressure Level  | dB  | MIN. 80  | at 30cm at Rated Voltage  | 
6  | Tone Nature  | Constant  | ||
7  | Operating Temperature  | ℃  | -20~ +60  | |
8  | Storage Temperature  | ℃  | -30 ~ +70  | |
9  | Dimension  | mm  | Φ22.7x H12.2  | See appearance drawing  | 
10  | Weight (MAX)  | gram  | 4.0  | |
11  | Housing Material  | ABS( Black )  | ||
12  | Leading Pin  | Wire Type  | See appearance drawing  | |
13  | Environmental    | RoHS  | 
 
C. APPEARANCE DRAWING  
Tol : ± 0.5 Unit: mm
D.TESTING METHOD    
Standard Measurement conditions
Temperature:25±2℃  Humidity:45-65%
Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the 
measuring instruments shown below
In the measuring test, buzzer is placed as follows:
 
E. VOLTAGE / CURRENT / SOUND PRESSURE CHARACTERISTICS
  
F. RELIABILITY TEST
NO.  | ITEM  | TEST CONDITION AND REQUIREMENT  | 
1  | High Temperature  | After being placed in a chamber with 70  | 
2  | Low Temperature  | After being Placed in a chamber with -30  | 
3  | Humidity Test  | After being Placed in a chamber with 90-95% R.H. at 40  | 
4  | Temperature Cycle  | The part shall be subjected to 5 cycles. One cycle shall be consist of:   | 
5  | Drop Test  | Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of 75cm .  | 
6  | Vibration Test  | After being applied vibration of amplitude of 1.5mmwith 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours .  | 
7  | Solderability  | Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +300  | 
8  | Terminal Strength  | The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10 seconds.  | 
TEST CONDITION. 
Standard Test Condition              :      a) Temperature : +5 ~ +35℃  b) Humidity : 45-85%        c) Pressure : 860-1060mbar 
Judgment Test Condition             :      a) Temperature : +25 ± 2℃    b) Humidity : 60-70%        c) Pressure : 860-1060mbar 
 
G. PACKING STANDARD 